CV432Sensibly equivalent¶ to:
|
|
|
The CV432 is an electrometer pentode for use in high resistance circuits for such applications as PH meters. The CV specification describes it as an HF pentode operating to 125 MHz., photocell units and valve voltmeters. The prototype was the VX8048.Reference: Data-sheet. |
Pin Connections
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | tc |  m | h | a | g2 | g3 | nc | h | k | g1 |
|
|
Absolute Maximum Operating Conditions¶
| Vh | Ah | Va | Vs | Vg | mAa | mAs | ra | gm | 
| 4.5 | 0.16 | 45 | 45 | -2 | 0.80 | 0.20 | 5,000 | 0.24 |
|
Absolute Maximum Operating Conditions¶
| Vh | Ah | Va | Vs | Vg | mAa | mAs | ra | gm | 
| 6.3 | - | 250 | 100 | -2 | 1.0 | - | 2.0M | 1.8 |
|
Updated January 08, 2022.
|
|